New Fashion Design For Underground Gas Pipe - Api 5l Line Pipes Grade B To X70 Od From 219mm To 3500mm – Spiral
New Fashion Design For Underground Gas Pipe - Api 5l Line Pipes Grade B To X70 Od From 219mm To 3500mm – Spiral Detail:
The Mechanical Properties of the SSAW pipe
steel grade |
minimum yield strength |
minimum Tensile strength |
Minimum Elongation |
B |
245 |
415 |
23 |
X42 |
290 |
415 |
23 |
X46 |
320 |
435 |
22 |
X52 |
360 |
460 |
21 |
X56 |
390 |
490 |
19 |
X60 |
415 |
520 |
18 |
X65 |
450 |
535 |
18 |
X70 |
485 |
570 |
17 |
The Chemical composition of the SSAW pipes
steel grade |
C |
Mn |
P |
S |
V+Nb+Ti |
Max % |
Max % |
Max % |
Max % |
Max % |
|
B |
0.26 |
1.2 |
0.03 |
0.03 |
0.15 |
X42 |
0.26 |
1.3 |
0.03 |
0.03 |
0.15 |
X46 |
0.26 |
1.4 |
0.03 |
0.03 |
0.15 |
X52 |
0.26 |
1.4 |
0.03 |
0.03 |
0.15 |
X56 |
0.26 |
1.4 |
0.03 |
0.03 |
0.15 |
X60 |
0.26 |
1.4 |
0.03 |
0.03 |
0.15 |
X65 |
0.26 |
1.45 |
0.03 |
0.03 |
0.15 |
X70 |
0.26 |
1.65 |
0.03 |
0.03 |
0.15 |
The Geometric tolerance of the SSAW pipes
Geometric tolerances |
||||||||||
outside diameter |
Wall thickness |
straightness |
out-of-roundness |
mass |
Maximum weld bead height |
|||||
D |
T |
|||||||||
≤1422mm |
>1422mm |
<15mm |
≥15mm |
pipe end 1.5m |
full length |
pipe body |
pipe end |
T≤13mm |
T>13mm |
|
±0.5% |
as agreed |
±10% |
±1.5mm |
3.2mm |
0.2% L |
0.020D |
0.015D |
‘+10% |
3.5mm |
4.8mm |
Hydrostatic Test
The pipe shall withstand the hydrostatic test without leakage through the weld seam or the pipe body
Jointers need not be hydrostatically tested, providedthat the portions of pipe used in marking the jointers were successfully hydrostatically tested prior to the joining operation.
Traceablity:
For PSL 1 pipe, the manufacturer shall establish and follow documented procedures for maintaining:
The heat identity until each related chmical tests is performed and conformance with the specified requirements is shown
The test-unit identity until each related mechanical tests is performed and conformance with the specified requirements is shown
For PSL 2 pipe, the manufacturer shall establish and follow documented procedures for maintaining the heat identity and the test-unit identity for such pipe. Such procedures shall provide means for tracing any length of pipe to the proper test unit and the related chemical test results.
Product detail pictures:

Related Product Guide:
The incredibly abundant projects administration experiences and 1 to one provider model make the superior importance of small business communication and our easy understanding of your expectations for New Fashion Design For Underground Gas Pipe - Api 5l Line Pipes Grade B To X70 Od From 219mm To 3500mm – Spiral , The product will supply to all over the world, such as: Belarus, Greek, Washington, We hope we can establish long-term cooperation with all of the customers. And hope we can improve competitiveness and achieve the win-win situation together with the customers. We sincerely welcome the customers from all over the world to contact us for anything you need!