OEM/ODM Factory The Pipe Line - Api 5l Line Pipes Grade B To X70 Od From 219mm To 3500mm – Spiral
OEM/ODM Factory The Pipe Line - Api 5l Line Pipes Grade B To X70 Od From 219mm To 3500mm – Spiral Detail:
The Mechanical Properties of the SSAW pipe
steel grade |
minimum yield strength |
minimum Tensile strength |
Minimum Elongation |
B |
245 |
415 |
23 |
X42 |
290 |
415 |
23 |
X46 |
320 |
435 |
22 |
X52 |
360 |
460 |
21 |
X56 |
390 |
490 |
19 |
X60 |
415 |
520 |
18 |
X65 |
450 |
535 |
18 |
X70 |
485 |
570 |
17 |
The Chemical composition of the SSAW pipes
steel grade |
C |
Mn |
P |
S |
V+Nb+Ti |
Max % |
Max % |
Max % |
Max % |
Max % |
|
B |
0.26 |
1.2 |
0.03 |
0.03 |
0.15 |
X42 |
0.26 |
1.3 |
0.03 |
0.03 |
0.15 |
X46 |
0.26 |
1.4 |
0.03 |
0.03 |
0.15 |
X52 |
0.26 |
1.4 |
0.03 |
0.03 |
0.15 |
X56 |
0.26 |
1.4 |
0.03 |
0.03 |
0.15 |
X60 |
0.26 |
1.4 |
0.03 |
0.03 |
0.15 |
X65 |
0.26 |
1.45 |
0.03 |
0.03 |
0.15 |
X70 |
0.26 |
1.65 |
0.03 |
0.03 |
0.15 |
The Geometric tolerance of the SSAW pipes
Geometric tolerances |
||||||||||
outside diameter |
Wall thickness |
straightness |
out-of-roundness |
mass |
Maximum weld bead height |
|||||
D |
T |
|||||||||
≤1422mm |
>1422mm |
<15mm |
≥15mm |
pipe end 1.5m |
full length |
pipe body |
pipe end |
T≤13mm |
T>13mm |
|
±0.5% |
as agreed |
±10% |
±1.5mm |
3.2mm |
0.2% L |
0.020D |
0.015D |
‘+10% |
3.5mm |
4.8mm |
Hydrostatic Test
The pipe shall withstand the hydrostatic test without leakage through the weld seam or the pipe body
Jointers need not be hydrostatically tested, providedthat the portions of pipe used in marking the jointers were successfully hydrostatically tested prior to the joining operation.
Traceablity:
For PSL 1 pipe, the manufacturer shall establish and follow documented procedures for maintaining:
The heat identity until each related chmical tests is performed and conformance with the specified requirements is shown
The test-unit identity until each related mechanical tests is performed and conformance with the specified requirements is shown
For PSL 2 pipe, the manufacturer shall establish and follow documented procedures for maintaining the heat identity and the test-unit identity for such pipe. Such procedures shall provide means for tracing any length of pipe to the proper test unit and the related chemical test results.
Product detail pictures:

Related Product Guide:
Together with the Client-Oriented enterprise philosophy, a arduous good quality control technique, sophisticated producing equipment and a sturdy R&D staff, we generally offer superior quality merchandise, superb solutions and aggressive rates for OEM/ODM Factory The Pipe Line - Api 5l Line Pipes Grade B To X70 Od From 219mm To 3500mm – Spiral , The product will supply to all over the world, such as: Rome, Japan, Johannesburg, Whether selecting a current product from our catalog or seeking engineering assistance for your application, you can talk to our customer service center about your sourcing requirements. We can provided good quality with competitive price for you personally.

The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.