Mechanical Property
steel grade |
minimum yield strength |
Tensile strength |
Minimum elongation |
Minimum impact energy |
||||
Specified thickness |
Specified thickness |
Specified thickness |
at test temperature of |
|||||
<16 |
>16≤40 |
<3 |
≥3≤40 |
≤40 |
-20℃ |
0℃ |
20℃ |
|
S235JRH |
235 |
225 |
360-510 |
360-510 |
24 |
- |
- |
27 |
S275J0H |
275 |
265 |
430-580 |
410-560 |
20 |
- |
27 |
- |
S275J2H |
27 |
- |
- |
|||||
S355J0H |
365 |
345 |
510-680 |
470-630 |
20 |
- |
27 |
- |
S355J2H |
27 |
- |
- |
|||||
S355K2H |
40 |
- |
- |
Chemical Composition
Steel grade |
Type of de-oxidation a |
% by mass, maximum |
||||||
Steel name |
Steel number |
C |
C |
Si |
Mn |
P |
S |
Nb |
S235JRH |
1.0039 |
FF |
0,17 |
— |
1,40 |
0,040 |
0,040 |
0.009 |
S275J0H |
1.0149 |
FF |
0,20 |
— |
1,50 |
0,035 |
0,035 |
0,009 |
S275J2H |
1.0138 |
FF |
0,20 |
— |
1,50 |
0,030 |
0,030 |
— |
S355J0H |
1.0547 |
FF |
0,22 |
0,55 |
1,60 |
0,035 |
0,035 |
0,009 |
S355J2H |
1.0576 |
FF |
0,22 |
0,55 |
1,60 |
0,030 |
0,030 |
— |
S355K2H |
1.0512 |
FF |
0,22 |
0,55 |
1,60 |
0,030 |
0,030 |
— |
a. The deoxidation method is designated as follows: FF: Fully killed steel containing nitrogen binding elements in amounts sufficient to bind available nitrogen (e.g. min. 0,020 % total Al or 0,015 % soluble Al). b. The maximum value for nitrogen does not apply if the chemical composition shows a minimum total Al content of 0,020 % with a minimum Al/N ratio of 2:1, or if sufficient other N-binding elements are present. The N-binding elements shall be recorded in the Inspection Document. |
Hydrostatic Test
Each length of pipe shall be tested by the manufacturer to a hydrostatic pressure that will produce in the pipe wall a stress of not less than 60% of the specified minimum yield strength at room temperature. The pressure shall be determined by the following equation:
P=2St/D
Permissible Variations In Weights and Dimensions
Each length of pipe shall be weighed separately and its weight shall not vary more than 10% over or 5.5% under its theoretical weight, calculated using its length and its weight per unit length
The outside diameter shall not vary more than ±1% from the specified nominal outside diameter
Wall thickness at any point shall not more than 12.5% under the specified wall thickness
Product detail pictures:
Related Product Guide:
We believe in: Innovation is our soul and spirit. Quality is our life. Customer need is our God for Well-Designed Gas Line Plumbing - Cold Formed Pipes, EN10219 S235JRH, S235J0H, S355JRH, S355J0H – Spiral , The product will supply to all over the world, such as: UK, America, Florence, Insisting on the high quality generation line management and customers expert assistance, we now have designed our resolution to offer our buyers using the to start with amount getting and just after services practical experience. Maintaining the prevailing friendly relations with our buyers, we however innovate our solution lists all of the time to satisfy the brand new demands and adhere to the most up-to-date development of the market in Malta. We are ready to face the worries and make the improve to understand all the possibilities in international trade.